Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.709
Filtrar
2.
World J Urol ; 42(1): 244, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38642145

RESUMO

PURPOSE: To compare vapor tunnel (VT) and virtual basket (VB) tools to reduce retropulsion in the treatment of proximal ureteral stones. METHODS: Patients with a single proximal ureteral stone were randomly assigned to holmium laser lithotripsy with the use of VT (Group A) or VB (Group B) tool. The 150W holmium:YAG cyber Ho generator was used. We compared operative time, dusting time, need for flexible ureteroscopy due to stone push-up and occurrence of ureteral lesions. The stone-free rate (SFR) and the occurrence of postoperative ureteral strictures were assessed. RESULTS: 186 patients were treated, of which 92 with the VT (49.5%, Group A) and 94 with the VB (50.5%, Group B). Mean stone size was 0.92 vs. 0.91 cm in Groups A vs. B (p = 0.32). Mean total operative time and dusting time were comparable between groups. 7 (7.6%) vs. 6 (6.4%) patients in Groups A vs. B required a flexible ureteroscope because of stone push-up (p = 0.12). Ureteral mucosa lesions were observed in 15 (16.3%) vs. 18 (19.1%) cases in the VT vs. VB group (p = 0.09). 1-Month SFR was comparable (97.8% vs. 95.7%, p = 0.41). We observed one case (1.1%) of postoperative ureteral stricture in the VT group vs. two cases (2.1%) in the VB group (p = 0.19). CONCLUSIONS: VT and VB are equally safe and effective tools in reducing retropulsion of ureteral stones. Operative time, dusting time and SFR were comparable. They also equally avoided stone push-up and prevented ureteral lesions, which may later occur in ureteral strictures.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Ureterais , Humanos , Hólmio , Lasers de Estado Sólido/uso terapêutico , Constrição Patológica/etiologia , Ureteroscopia/efeitos adversos , Resultado do Tratamento , Cálculos Ureterais/cirurgia , Litotripsia a Laser/efeitos adversos , Complicações Pós-Operatórias/etiologia
3.
Med Sci Monit ; 30: e942836, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38632864

RESUMO

BACKGROUND Patients with urolithiasis often undergo transurethral ureteroscopic holmium laser lithotripsy, a procedure that can be affected by perioperative thermal management. This study examines the impact of compound thermal insulation management on patient recovery and comfort during transurethral ureteroscopic holmium laser lithotripsy. MATERIAL AND METHODS In this study, 551 patients who underwent transurethral ureteroscopic holmium laser lithotripsy from April 2019 to December 2022 were randomly assigned to either an observation group (n=276) or control group (n=275). Both groups received routine surgical care, with the observation group additionally receiving compound thermal insulation management. We recorded and compared perioperative body temperature changes, anesthetic resuscitation indicators (bispectral index recovery time, extubation time, fully awake time, Postanesthesia Care Unit retention time), comfort level (General Comfort Questionnaire), and quality of life (Nottingham Health Profile). We also compared the incidence of complications. RESULTS There was no significant difference in body temperature between groups at the start surgery. However, the observation group showed significantly higher temperatures during and at the end of surgery. Anesthetic resuscitation indicators were significantly better in the observation group. Both groups showed improved comfort and quality of life after surgery, with more significant improvements in the observation group. The observation group also had a lower incidence of complications, such as hypothermia and rigor. CONCLUSIONS Compound thermal insulation management during transurethral ureteroscopic holmium laser lithotripsy improved perioperative temperature maintenance, accelerated postoperative recovery, reduced complication rates, and enhanced patient comfort and quality of life.


Assuntos
Anestésicos , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Litotripsia a Laser/métodos , Hólmio , Qualidade de Vida , Ureteroscopia/métodos
5.
World J Urol ; 42(1): 197, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38530484

RESUMO

INTRODUCTION: High fluid temperatures have been seen in both in vitro and in vivo studies with laser lithotripsy, yet the thermal distribution within the renal parenchyma has not been well characterized. Additionally, the heat-sink effect of vascular perfusion remains uncertain. Our objectives were twofold: first, to measure renal tissue temperatures in response to laser activation in a calyx, and second, to assess the effect of vascular perfusion on renal tissue temperatures. METHODS: Ureteroscopy was performed in three porcine subjects with a prototype ureteroscope containing a temperature sensor at its tip. A needle with four thermocouples was introduced percutaneously into a kidney with ultrasound guidance to allow temperature measurement in the renal medulla and cortex. Three trials of laser activation (40W) for 60 s were conducted with an irrigation rate of 8 ml/min at room temperature in each subject. After euthanasia, three trials were repeated without vascular perfusion in each subject. RESULTS: Substantial temperature elevation was observed in the renal medulla with thermal dose in two of nine trials exceeding threshold for tissue injury. The temperature decay time (t½) of the non-perfused trials was longer than in the perfused trials. The ratio of t½ between them was greater in the cortex than the medulla. CONCLUSION: High-power laser settings (40W) can induce potentially injurious temperatures in the in vivo porcine kidney, particularly in the medullary region adjacent to the collecting system. Additionally, the influence of vascular perfusion in mitigating thermal risk in this susceptible area appears to be limited.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Suínos , Animais , Humanos , Temperatura , Temperatura Alta , Rim , Ureteroscopia , Perfusão
6.
Urolithiasis ; 52(1): 50, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38554174

RESUMO

The purpose of this study was to evaluate the efficacy and safety of flexible ureteroscopy with holmium laser lithotripsy in the management of calyceal diverticular calculi. In this study, we retrospectively analyzed the clinical data of 27 patients with calyceal diverticular calculi admitted to the Department of Urology of the Zigong First People's Hospital from May 2018 to May 2021. Intraoperatively, the diverticular neck was found in all 27 patients, but flexible ureterorenoscopy lithotripsy was not performed in 2 cases because of the slender diverticular neck, and the success rate of the operation was 92.6%. Of the 25 patients with successful lithotripsy, the mean operative time was 76.9 ± 35.5 (43-200) min. There were no serious intraoperative complications such as ureteral perforation, mucosal avulsion, or hemorrhage. Postoperative minor complications (Clavien classification I-II) occurred in 4 (16%) patients. The mean hospital stay was 4.4 ± 1.7 (3-12) days. The stone-free rate was 80% at the 1-month postoperative follow-up. After the second-stage treatment, the stone-free rate was 88%. In 22 cases with complete stone clearance, no stone recurrence was observed at 5.3 ± 2.6 (3-12) months follow-up. This retrospective study demonstrated that flexible ureterorenoscopy with holmium laser is a safe and effective choice for the treatment of calyceal diverticular calculi, because it utilizes the natural lumen of the human body and has the advantages of less trauma, fewer complications, and a higher stone-free rate.


Assuntos
Divertículo , Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Ureterais , Humanos , Ureteroscopia/efeitos adversos , Estudos Retrospectivos , Lasers de Estado Sólido/efeitos adversos , Cálculos Renais/terapia , Ureteroscópios , Litotripsia a Laser/efeitos adversos , Divertículo/cirurgia , Divertículo/complicações , Complicações Pós-Operatórias , Cálculos Ureterais/complicações , Resultado do Tratamento
8.
Urolithiasis ; 52(1): 49, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520506

RESUMO

As laser technology has advanced, high-power lasers have become increasingly common. The Holmium: yttrium-aluminum-garnet (Ho:YAG) laser has long been accepted as the standard for laser lithotripsy. The thulium fiber laser (TFL) has recently been established as a viable option. The aim of this study is to evaluate thermal dose and temperature for the Ho:YAG laser to the TFL at four different laser settings while varying energy, frequency, operator duty cycle (ODC). Utilizing high-fidelity, 3D-printed hydrogel models of a pelvicalyceal collecting system (PCS) with a synthetic BegoStone implanted in the renal pelvis, laser lithotripsy was performed with the Ho:YAG laser or TFL. At a standard power (40W) and irrigation (17.9 ml/min), we evaluated four different laser settings with ODC variations with different time-on intervals. Temperature was measured at two separate locations. In general, the TFL yielded greater cumulative thermal doses than the Ho:YAG laser. Thermal dose and temperature were typically greater at the stone when compared away from the stone. Regarding the TFL, there was no general trend if fragmentation or dusting settings yielded greater thermal doses or temperatures. The TFL generated greater temperatures and thermal doses in general than the Ho:YAG laser with Moses technology. Temperatures and thermal doses were greater closer to the laser fiber tip. It is inconclusive as to whether fragmentation or dusting settings elicit greater thermal loads for the TFL. Energy, frequency, ODC, and laser-on time significantly impact thermal loads during ureteroscopic laser lithotripsy, independent of power.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Túlio , Hólmio , Hidrogéis , Rim/cirurgia , Lasers de Estado Sólido/uso terapêutico
9.
World J Urol ; 42(1): 157, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483596

RESUMO

PURPOSE: To evaluate the thermal profiles of the holmium laser at different laser parameters at different locations in an in vitro anatomic pelvicalyceal collecting system (PCS) model. Laser lithotripsy is the cornerstone of treatment for urolithiasis. With the prevalence of high-powered lasers, stone ablation efficiency has become more pronounced. Patient safety remains paramount during surgery. It is well recognized that the heat generated from laser lithotripsy has the potential to cause thermal tissue damage. METHODS: Utilizing high-fidelity, 3D printed hydrogel models of a PCS with a synthetic BegoStone implanted in the renal pelvis, laser lithotripsy was performed with the Moses 2.0 holmium laser. At a standard power (40 W) and irrigation pressure (100 cm H2O), we evaluated operator duty cycle (ODC) variations with different time-on intervals at four different laser settings. Temperature was measured at two separate locations-at the stone and away from the stone. RESULTS: Temperatures were highest closest to the laser tip with a decrease away from the laser. Fluid temperatures increased with longer laser-on times and higher ODCs. Thermal doses were greater with increased ODCs and the threshold for thermal injury was reached for ODCs of 75% and 100%. CONCLUSION: Temperature generation and thermal dose delivered are greatest closer to the tip of the laser fiber and are not dependent on power alone. Significant temperature differences were noted between four laser settings at a standardized power (40 W). Temperatures can be influenced by a variety of factors, such as laser-on time, operator duty cycle, and location in the PCS.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Hólmio , Lasers de Estado Sólido/uso terapêutico , Modelos Anatômicos
10.
BMC Urol ; 24(1): 54, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454412

RESUMO

BACKGROUND: For renal stones > 20 mm, percutaneous nephrolithotomy (PNL) offers the best stone clearance rates with acceptable complication rates. This study aimed to compare the efficiency of high-power holmium YAG laser and ballistic lithotripsy during mini-PNL. METHODS: Data from 880 patients who underwent mini-PNL for renal stones was investigated retrospectively. The study utilized propensity score matching to create two groups: laser lithotripsy (n = 440) and ballistic lithotripsy (n = 440). The groups were matched based on stone size, Guy's stone score, and stone density. The main objectives of the study were to assess the stone-free rate (SFR), duration of surgery, and complication rates. RESULTS: The average age of the population was 51.4 ± 7.1 years, with a mean stone size of 28.6 ± 8.3 mm and a mean stone density of 1205 ± 159 HU. There were no significant differences between the groups. The SFRs of the laser lithotripsy and ballistic lithotripsy were 92.5% and 90.2%, respectively (p = 0.23). The laser lithotripsy group had a notably shorter surgery time (40.1 ± 6.3 min) compared to the ballistic lithotripsy group (55.6 ± 9.9 min) (p = 0.03). Complication rates were similar (p = 0.67). CONCLUSIONS: Our study shows that a high-power holmium YAG laser provides quicker operation time compared to ballistic lithotripsy. However, ballistic lithotripsy is still an effective and safe option for stone fragmentation during mini-PNL. In places where a high-power holmium YAG laser is not available, ballistic lithotripters are still a safe, effective, and affordable option for mini-PNL.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Nefrolitotomia Percutânea , Humanos , Adulto , Pessoa de Meia-Idade , Nefrolitotomia Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento , Cálculos Renais/cirurgia , Litotripsia/métodos , Lasers de Estado Sólido/uso terapêutico
11.
World J Urol ; 42(1): 143, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478076

RESUMO

PURPOSE: To present the initial prospective clinical assessment of the ILY® robotic ureteroscopy manipulator platform, focusing on its safety and effectiveness. METHODS AND MATERIALS: Data gathered from 31 kidney units which underwent elective robotic flexible ureteroscopy (FURS) for renal stone management utilizing the ILY® robotic system. Patient demographics, stone characteristics, surgical durations, perioperative and post-operative complications, and follow-up parameters were collected. Our primary outcome was evaluating the efficacy and safety of the ILY® robotic ureteroscopy for treating kidney stones. Therefore, we analyzed complication rates, surgical durations, and the stone-free rate during follow-up. RESULTS: Our cohort consisted of 29 patients, presenting with 45 stones with a median volume of 736.22 mm3. The median operation time was 85 min, accompanied by 3 min for robot draping, 3.5 min for robot docking, 48 min of console operation, and lasing time of 36.75 min. Post operative stay for all patients was 1 day, while complications were observed in 9.68% of cases. Notably, all complications were classified as CVD (Clavien-Dindo) class 1 due to pain requiring emergency department visit. The stone-free rate achieved was 93.55%, and none of the patient required reoperation for the treated stone. CONCLUSION: In the first prospective clinical experience of the ILY® robotic FURS, we demonstrated its efficacy and safety. To further investigate its clinical practical value, additional investigations are warranted, including direct comparative analyses with manual flexible ureteroscopy techniques.


Assuntos
Cálculos Renais , Litotripsia a Laser , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Ureteroscopia/métodos , Estudos Prospectivos , Litotripsia a Laser/métodos , Resultado do Tratamento , Cálculos Renais/terapia , Estudos Retrospectivos
12.
World J Urol ; 42(1): 145, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478094

RESUMO

INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Túlio/uso terapêutico , Litotripsia a Laser/métodos , Cálculos Renais/cirurgia
13.
Medicina (Kaunas) ; 60(2)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38399633

RESUMO

Background and Objectives: While studies have demonstrated the efficacy of cholangioscopy-guided Holmium-Yttrium aluminum garnet (Ho:YAG) laser lithotripsy for the treatment of refractory bile duct stones, data regarding the safety of the operating parameters for laser lithotripsy are lacking. The aim of this study was to determine safe, yet effective, energy settings for Ho:YAG laser in the ex-vivo model. Materials and Methods: This ex vivo experimental study utilized the Ho:YAG laser on porcine bile duct epithelium and human gallstones. Ho:YAG laser lithotripsy was applied in different power settings from 8 to 15 Watts (W) to six explanted porcine bile ducts. Settings that appeared safe were then utilized to fragment seventy-three human gallstones. Results: The median bile duct perforation times with the Ho:YAG laser between 8-15 W were: >60 s (8 W); 23 s (9 W); 29 s (10 W); 27 s (12 W); 12 s (14 W); and 8 s (15 W). Statistically significant differences in the median perforation times were noted between 8 W vs. 15 W, 9 W vs. 15 W, 10 W vs. 15 W, and 12 W vs. 15 W (p < 0.05). When using a 365 µm Ho:YAG laser probe at 8-12 W, the fragmentation rates on various size stones were: 100% (<1.5 cm); 80-100% (1.6-2.0 cm) and 0-32% (>2.0 cm). Optimal fragmentation was seen utilizing 12 W with high energy (2.4 J) and low frequency (5 Hz) settings. Using a larger 550 µm probe at these settings resulted in 100% fragmentation of stones larger than 2 cm. Conclusions: The Ho:YAG laser appears to be safe and effective in the treatment of large bile duct stones when used between 8-12 W in 5 s bursts in an ex vivo model utilizing porcine bile ducts and human gallstones.


Assuntos
Cálculos Biliares , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Suínos , Animais , Cálculos Biliares/cirurgia , Lasers de Estado Sólido/uso terapêutico , Hólmio , Litotripsia a Laser/métodos
16.
Urology ; 186: 117-122, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38417468

RESUMO

OBJECTIVE: To compare same-sitting bilateral vs unilateral retrograde intrarenal surgery (RIRS) in elderly patients, focusing on postoperative complications and stone-free rates (SFR). METHODS: Data from 2 multicenter databases, FLEXible ureteroscopy Outcomes Registry (FLEXOR) (unilateral RIRS) and same sitting bilateral-retrograde intrarenal surgery (SSB-RIRS) (bilateral RIRS), were analyzed, considering only patients aged 70+ with preoperative computed tomography. Patients were categorized into Group 1 (bilateral RIRS) and Group 2 (unilateral RIRS). Follow-up included imaging assessments and secondary treatments as needed. RESULTS: Group 1 included 146 patients, while group 2 had 495. Group 1's patients were slightly older and had a higher prevalence of recurrent stone formation. Group 2 often underwent RIRS for incidental stones. Group 1 had larger and more pelvic stones. Laser lithotripsy and total operation times were significantly longer in Group 1. Group 2 had significantly higher overall stone-free rates, although there were no significant differences in ancillary procedures for residual fragments. Group 1 experienced more pelvicalyceal injuries needing stenting, postoperative fever, and post-op hematuria not requiring transfusion. CONCLUSION: In conclusion, bilateral RIRS can be carefully considered in elderly patients. Preoperative counseling is essential for both primary and repeat RIRS procedures, and further research is needed to optimize instrument and laser strategies for better outcomes in elderly RIRS patients.


Assuntos
Cálculos Renais , Litotripsia a Laser , Litotripsia , Idoso , Humanos , Cálculos Renais/terapia , Postura Sentada , Litotripsia/métodos , Hematúria/etiologia , Resultado do Tratamento
17.
World J Urol ; 42(1): 96, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38386126

RESUMO

The introduction of the Ho:YAG laser 3 decades ago revolutionized the endoscopic treatment of urolithiasis. Since then, a variety of innovations have continued to evolve these devices, including the development of high-power lasers capable of high-frequency lithotripsy. The clinical utility of high-frequency lithotripsy, however, has not necessarily lived up to the potential suggested by in vitro studies. A review of the relevant literature, confirming strong similarities between the outcomes associated with high and lower power laser lithotripsy, follows.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Urolitíase , Humanos , Lasers de Estado Sólido/uso terapêutico , Projetos de Pesquisa , Urolitíase/cirurgia
18.
BMC Urol ; 24(1): 44, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38374098

RESUMO

OBJECTIVES: To compare the efficacy and safety of thulium fiber laser (TFL) to holmium: YAG (Ho: YAG) laser in ureteroscopic lithotripsy for urolithiasis. METHODS: PubMed, Web of Science, Embase, CENTRAL, SinoMed, CNKI database, VIP and Wanfang Database were systematically searched for all relevant clinical trials until September 2023. References were explored to identify the relevant articles. Meta-analysis was carried out for the retrieved studies using RevMan5.4.1 software, and the risk ratio, mean difference and 95% confidence interval were expressed. Statistical significance was set at p < 0.05. The main outcomes of this meta-analysis were stone-free rate (SFR), perioperative outcomes and intraoperative or postoperative complications. RESULTS: Thirteen studies, including 1394 patients, were included. According to the results of pooled analysis, TFL was associated with significantly higher stone-free rate (SFR) [0.52, 95% CI (0.32, 0.85), P = 0.009], shorter operation time [-5.47, 95% CI (-8.86, -2.08), P = 0.002], and less stone migration [0.17, 95% CI (0.06, 0.50), P = 0.001]. However, there was no significant difference in terms of the laser time, duration of hospital stay, drop of hemoglobin level, total energy, postoperative ureteral stenting, the incidence of intraoperative complications or postoperative complications between TFL and Ho: YAGs. CONCLUSION: The findings of this study demonstrated several advantages of TFL in terms of higher SFR, shorter operative time and less stone migration. TRIAL REGISTRATION: The protocol of this systematic review was listed in PROSPERO ( www.crd.york.ac.uk/PROSPERO ) (Protocol number: CRD42022362550).


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Litotripsia a Laser/métodos , Ureteroscopia/métodos , Complicações Pós-Operatórias/epidemiologia
19.
J Endourol ; 38(4): 308-315, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38185920

RESUMO

Objective: The primary aim of the study was to explore intrarenal temperatures (IRTs) during flexible ureteroscopic laser lithotripsy (FURSL). The secondary aim was to investigate the correlation between temperatures and renal pelvis anteroposterior diameter (APD). Materials and Methods: From February 2023 to June 2023, 10 patients with an indwelling nephrostomy tube (NT) undergoing FURSL were enrolled in the study. Sheathless FURSL was performed using gravitational irrigation (23°C) at 60 cm. A sterile K-type thermocouple was inserted through the NT. Temperatures were recorded for 120 seconds with continuous laser activation and for another 60 seconds after deactivation. Thulium fiber laser delivered energy using a 150 µm fiber and incremental power settings of 5, 10, 20, and 30 W. The laser was deactivated whenever the IRT reached 43°C. Results: IRT correlated directly to power settings. Each time the power settings were increased, the temperature rose significantly. The increase in average peak temperature was 2.6°C between 5 and 10 W (p < 0.001), 3.4°C between 10 and 20 W (p < 0.001), and 2.5°C between 20 and 30 W (p < 0.001). Temperatures reached 43°C in three patients applying 20 W and in eight patients applying 30 W. The shortest activation-time until threshold was 12 and 28 seconds with 30 and 20 W settings, respectively. When reaching 43°C, temperatures remained above this threshold for an additional 29 seconds on average. There was a significant correlation between IRT and renal APD. For example, when 10 W was applied in the setting of APD ≤20 mm, the recorded temperature was on average 2.3°C higher compared with APD >20 mm, with the same power settings applied, p < 0.001. Conclusion: During FURSL, IRT correlates directly with power settings and is inversely correlated with renal pelvic APD. Using a sheathless approach, power settings ≥20 W should arguably be avoided, especially in the context of a nondilated renal pelvis. ClinicalTrials: The study was registered on ClinicalTrials.gov (NCT05677425).


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Temperatura Alta , Estudos Prospectivos , Temperatura , Ureteroscopia
20.
World J Urol ; 42(1): 33, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217743

RESUMO

PURPOSE: To identify laser lithotripsy settings used by experts for specific clinical scenarios and to identify preventive measures to reduce complications. METHODS: After literature research to identify relevant questions, a survey was conducted and sent to laser experts. Participants were asked for preferred laser settings during specific clinical lithotripsy scenarios. Different settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-six laser experts fully returned the survey. Holmium-yttrium-aluminum-garnet (Ho:YAG) was the primary laser used (88%), followed by thulium fiber laser (TFL) (42%) and pulsed thulium-yttrium-aluminum-garnet (Tm:YAG) (23%). For most scenarios, we could not identify relevant differences among laser settings. However, the laser power was significantly different for middle-ureteral (p = 0.027), pelvic (p = 0.047), and lower pole stone (p = 0.018) lithotripsy. Fragmentation or a combined fragmentation with dusting was more common for Ho:YAG and pulsed Tm:YAG lasers, whereas dusting or a combination of dusting and fragmentation was more common for TFL lasers. Experts prefer long pulse modes for Ho:YAG lasers to short pulse modes for TFL lasers. Thermal injury due to temperature development during lithotripsy is seriously considered by experts, with preventive measures applied routinely. CONCLUSIONS: Laser settings do not vary significantly between commonly used lasers for lithotripsy. Lithotripsy techniques and settings mainly depend on the generated laser pulse's and generator settings' physical characteristics. Preventive measures such as maximum power limits, intermittent laser activation, and ureteral access sheaths are commonly used by experts to decrease thermal injury-caused complications.


Assuntos
Alumínio , Lasers de Estado Sólido , Litotripsia a Laser , Urolitíase , Ítrio , Humanos , Túlio , Urolitíase/cirurgia , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Tecnologia , Hólmio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...